Stainless steel and is backed by a lifetime warranty.
Chimney liners for open fireplaces.
The rule of thumb for sizing a chimney liner is that you never want it to be smaller than the appliance exhaust hole and you don t want the liner to be three times the area of the exhaust hole of the appliance.
It is flexible for relining masonry chimneys.
Open fires with larger fireplace openings usually freestanding grates will need larger flue sizes calculated alongside the height of the chimney and required ventilation.
Open wood burning and coal fires require a class 1 flue liner with a minimum diameter of 200mm.
Most british open fires were and still are designed to burn coal at up to 25 efficiency.
The ideal flue size is typically determined by the exhaust outlet of the stove or appliance.
A liner going to an insert or stove in the fireplace will be measured from the top of the chimney to the top of the insert or stove or the center of the hole on the back of the stove.
The tile liners used in most masonry fireplaces are fine as long as the fireplace is properly maintained and not exposed to chimney fires.
For chimneys more than 40 inches 1016 mm wide two additional no.
Please remember these liners are sold in 5 increments 15 20 25 so for instance an 18 chimney will need a 20 liner.
The forever cap flex all single ply 4 in.
B flue must be high enough for sufficient draught around 4 5m in most cases.
Flex all stainless steel chimney liner 6 in.
4 vertical bars shall be provided for each additional flue incorporated into the chimney or for each additional 40 inches 1016 mm in width or fraction thereof.
A handy breakdown of the components of a chimney.
C flue connector connects the fireplace to the flue.
The general rule of thumb is that a masonry fireplace should be swept before 1 8 of soot accumulates.
A flue lining usually made of refractory concrete or impervious clay.
Smooth wall fireplace stainless steel chimney liner kit model sw620sskf 423 16 423 16.
Kit is made of single ply 316 0 006 in.
Grout shall be prevented from bonding with the flue liner so that the flue liner is free to move with thermal expansion.
Standard for chimneys fireplaces vents and solid fuel burning appliances nfpa 211 reduces fire hazards by ensuring the safe removal of flue gases the proper installation of solid fuel burning appliances and the correct construction and installation of chimneys fireplaces and venting systems.
One good chimney fire will usually crack these tiles rendering them ineffective.
Chim cap corp 6 in.
Understanding chimney components image credit.
Set your store to see local availability add to cart.